FOX-2001 |
FOX-2001D |
FOX-2001T |
FOX-2001F |
FOX-2000TT |
Size & Dimension(mm) |
77(W) X 35(H) X 80(D) |
Operating Range |
-55.0~99.9 °C |
Input Sensor |
NTC (wire length : 3M) |
Display Accuracy |
±1% rdg ± 1 digit |
Output |
1relay(1a)250 VAC 2A (1 out) |
2relay(2a)250 VAC 2A (2 out) |
3relay(3a)250 VAC 2A (3 out) |
4relay(3a)250 VAC 2A (4 out) |
2relay(2a)250 VAC 2A (2 out) |
Control Method |
ON / OFF |
Cutting Size(mm) |
71(W) X 29(H) |
Power Supply |
230VAC 50/60Hz, {order porduction:110VAC 50/60Hz, 12or24V AC/DC ± 10% } |
Programming |
Set / Up /Down Key |
°C/ Up/Down/T/ Key |
Ambient Temp / Humi |
0~55 °C (32~131 °F)35~80% RH |
1PCS Weight (include Box) |
245g |
250g |
255g |
310g |
260g |
Functions |
Setting function for the highest & Lowest limit of temperature range |
2-stage temperature control |
3-stage temperature control |
4-stage temperature control |
control by temperature, time |
lock function of programs / correction of the present temperature |
|
FOX-2002 |
FOX-2003 |
FOX-2004 |
FOX-2005 |
FOX-2006 |
Size & Dimension(mm) |
77(W) X 35(H) X 80(D) |
Operating Range |
-55.0~99.9 °C |
Input Sensor |
NTC (wire length : 3M) |
NTC:2EA (2 sensor) |
Display Accuracy |
±1% rdg ± 1 digit |
Output |
2relay(2a)250 VAC 2A 1R:Temp, 2R:Alarm |
3relay(3a)250 VAC 2A |
4relay(1C,3a)250 VAC 2A |
1R:Temp 2R:Defrost 3R:FAN |
1R:Temp,2R:Defrost, 3R:FAN,4R:Alarm |
1R:Temp1,2RAlarm1, 3R:Temp2,4R:Alarm2 |
Control Method |
ON / OFF |
Cutting Size(mm) |
71(W) X 29(H) |
Power Supply |
230VAC 50/60Hz, {order porduction:110VAC 50/60Hz, 12 or 24V AC/DC ± 10% } |
Programming |
Set / Up /Down Key |
Set / Up /Down Key |
Set / Up /Down Key |
Ambient Temp / Humi |
0~55 °C (32~131 °F)35~80% RH |
1PCS Weight (include Box) |
260g |
265g |
290g |
315g |
315g |
Functions |
control for cooling & heating alarm temp. output |
only use cooling |
2 sensor ( temperature sensor, a preventive sensor for super-heating of defrosting) |
2 sensor (temperature sensor, evaporator's temperature sensor) alarm output function |
2 sensor (temperature 1,2)2channel selection of alarm function or 2-stage temperature setting |
FAN control output/defrosting function/only use cooling/manual defrosting function |
Setting function for the highest & Lowest limit of temperature range |
|
查看评论 |
|
|
如果您用过本商品,或对本商品有所问题,欢迎发表自己的评论和问题。我们会及时对您提出的问题解答,对您的评论给予鼓励。谢谢对本站的支持。 |
|
|
1.根据您的需要产品,请选定型号;
2.与我司销售人员或技术人员确认您的产品的功能,参数.
3.根据产品名称,产品型号签订购销合同
4.汇款后将汇款底联和合同;收货人地址;开票信息;发货方式传真
直线传真:0760-88306579 分机传真:0760-88886370 88886371 88886372 88886373转807分机
上海办事处传真(FAX): 15382730581 |
售后服务热线:0760-0760-88886370 88886371 88886372 88886373-805 806 803分机 移动电话:15382730581 15377871867
公司直线传真:0760-88306579 公司分机传真:0760-88886370 88886371 88886372 88886373转807分机 联系电话(TEL): 15382730581 15377871867
邮政编码: 528400 公司邮箱:459382380@qq.com 客服QQ:459382380 和 568843411 |