SCONI-1500多积积分MULTI INTEGRATING TOTALIZER
Features It is able to 10 digit total integration and 4 digit rate display.. It can be accepts multi input signal such as pulse, mA, Volt signal. It is improved reliability by use of high resolution V/F converter. It contains various batch function which can be use of various purposes. It is able to RS 422/485 communication function which can be use of remote control and monitoring . It can be install 2 alarm point which can be set up rate alarm, batch function and dead band. It can be install isolated current, voltage output and also possible output scaling. It has pulse output function which can be outputs external integrating total.
SCONI - 1 500 - □ □ - □ Input signal Output signal (1) Output signal (2) Power supply Name of each part Type Range Value Display DC 4 ~ 20mA mA / Volt DC 1~5V 0 ~ 9999 RNG0 Pulse 1 0.1 ~ 10Hz 0 ~ 9999 RNG1 Pulse 2 1 ~ 100Hz 0 ~ 9999 RNG2 Pulse 3 10 ~ 1KHz 0 ~ 9999 RNG3 1 2 Alarm (SPST) R Other N Not used 1 DC 1 ~ 5V 2 DC 4 ~ 20mA 3 RS - 422 / 485 R Other N Not used Features It is able to 10 digit total integration and 4 digit rate display.. It can be accepts multi input signal such as pulse, mA, Volt signal. It is improved reliability by use of high resolution V/F converter. It contains various batch function which can be use of various purposes. It is able to RS 422/485 communication function which can be use of remote control and monitoring . It can be install 2 alarm point which can be set up rate alarm, batch function and dead band. It can be install isolated current, voltage output and also possible output scaling. It has pulse output function which can be outputs external integrating total. X AC 110V / 220V Y DC 24V mA , Volt Multi Pulse ① Total count display ② Rate value display ③ Pulse output display ④ Alarm status display ⑤ Total count / Reset count display ⑥ ⑦ ⑧ ⑨ : Set up data and change key
General Specification Terminal connection Main functions Rate scaling function - In case of input is mA/Volt : This function changes and set up rate value as scale and input range change. - In case of input is pulse : This function converts input pulse count into rate value which calculates count factor and Rate time unit. Function LIN It transfers input value into output without any operation. It is used to input process which requires linearity and general measurement. Root It transfers input by square root and used to measure flow with orifice. Limit This function displays zero when does not need under display such as level measurement. Integration function - In case of input is current and voltage(mA, Volt) : It integrates rate value by compensation of time unit and integration rate. - In case of input is pulse : It integrates input pulse by dividing total unit per pulse(count factor). Alarm mode and batch function - Rate Alarm(2 Point) : There are 2 alarm point which can be set up upper and lower limit respectively. And also outputs relay contact output in compare with rate value. - Count Alarm + Rate Alarm : Alarm 1 is an over alarm for reset count value and alarm 2 is an alarm for rate value. Alarm 2 operates exactly same as rate alarm. Alarm 1 operates when reset count value over set up value. - 2 Count Alarm : Alarm 1,2 are over alarms for reset count value and operates when reset count value over set up value. Alarm is reseted when resets reset count. - Batch (Dosage) : It is possible sequential process with this function when fills a vessel with a fixed rate. It can be control of flow when approachs target value by 2 output contacts for precision control. Communication function It can be install communication function which can be use of remote control in connection with computer. Item Specification Input Resistance Volt(mA) Input : 250Ω Pulse Input : 10㏀ Measure/Display Period Rate value : 200ms(Volt, mA, Input) Total count : 1s(Volt, mA, Input) (Pulse input depends on frequency) CMRR More than 140dB NMRR More than 60dB Filter Transfer average filter Sensor Power DC 12V/30㎃/±0.5% Rate Linearity : 0.05% FS Repeatability : 0.1% FS Temperature Drift : 0.02% FS/℃ Long term drift : 0.1%/per 1000hr Totalize Function Data Storage : More than 10yrs Max Count : 10 Digit Pulse Output Output type : Isolated open collector Rating : Max DC 50V/50mA Max freq : Less than 5Hz Communication RS - 422/485 (4800 bps) Relay Contact AC 125V(2A) , DC 30V(3A) 4~20mA DC(0 ~ Load 600Ω) Resistance 0~10V DC(1㏀ or more) Isolation Input/Output, DC 500V More than 100㏁ Dielectric Strength Input/Output/Power, AC 1500V/ min AC 110/220V ±10%(50/60Hz) 4VA Power Supply DC 24V ±10%, Less than 100mA Operating Temp -10 ~ 60℃ Operating Humidity 10 ~ 90% Weight Approx 500gr(AC), 300gr(DC) Material/Color ABS Resin / Black Dimension W 96 x H 48 x D 112 (mm) Mounting Panel Flush 1 2 3 4 5 6 7 11 12 13 14 15 16 17 8 9 10 OUTPUT2 RS485 (Open. C) + DC 20-30V* FG AC 110V + AC 220V POWER SOURCE - 18 19 20 + - + + - + - PULSE 통신 V, mAPulse RESET O.C 1㏀ IN1 IN2 DC 12V OUTPUT1 AL 1 AL 2 (AO)
|