Easy-to-seelargesizeLED4pointsofalarmcanbeaddedOptionaldigitalcommunications
Input (2) Sampling cycle (3) Influence of external resistance (4) Influence of input lead (5) Action at input break (6) Action at input short circuit (7) PV bias : a)Thermocouple : K,J,E,T,R,S,B,N (JIS/IEC) U,L(DIN), PLII(NBS), W5Re/W26Re(ASTM) (Input impedance : Approx.1M ) b)RTD:Pt100(JIS/IEC),JPt100(JIS) c)Voltaga input : 0 to 5V DC, 1 to 5V DC d)Current input : 0 to 20mA DC, 4 to 20mA DC A resistor of 250 is to be connected externally. : 0.5 sec : Approx. 0.2 V/ (Thermocouple) : Approx. 0.01%/ of reading but up to 10 per wire maximum : a) Thermocouple : Up scale b) RTD : Up scale c) Voltage, current input : Down scale Alarm output is ON. When "0 to 5V DC" and "0 to 20mA DC" input, value around zero. : Down scale (RTD) Alarm output is ON : a) -1999 to 9999 or -199.9 to 999.9 C[ F] (Temperature) : b) -span to + span (voltage, current input) §Ù §Ù §Ù §Ù §Ù o o Performance (1) Measuring accuracy (2) Insulation resistance (3) Withstand voltage LEDdrive power supply for SP400/SP500 (option) (1) Output (2) Number of link When this option is specified, alarm 4 output is not available. Alarmfunction (option) (1) Number of output (2) Alarm action (3) Alarm differential gap (4) Alarm output Digital communications (option) (1) Communication method (2) Synchronous method (3) Communication speed (4) Bit format (5) Maximum connection : RS-485 (2 wires) : Start/stop synchronous type : 2400bps, 4800bps, 9600bps, 19200bps : Start bit : 1 Data bit : 7 or 8 Parity bit : odd, even or without Stop bit : 1 or 2 : 31 (Address can be set from 0 to 99.) Analog output (option) (1) Number of output (2) Output signal (3) Output scaling (4) Output resolution When this option is specified, alarm 3 is not available. : 1 point : 0 to 20mA DC, 4 to 20mA DC (Load resistance : less than 600 ) : Available for high and low limit. : More than 10bits. §Ù Dustproof and waterproof (option) Dustproof and waterproof protection : IP65 * Dustproof and waterproof are effective only to the front direction when installed on a panel. * Dustproof and waterproof are not effective when indicators are mounted in closely contacted. General specifications (option) (1) Supply voltage (2) Power consumption (3) Effect of power failure (4) Memory backup (5) Ambient temperature (6) Ambient humidity (7) (8) Operating environment (9) Other conditions Weight and external dimensions : a) AC type : 85 to 264V AC (50/60Hz common) (Including supply voltage variation) (Rating : 100 to 240V AC) b) 24V AC type : 21.6 to 26.4V AC (50/60Hz common) (Including supply voltage variation) (Rating : 24V AC) c) 24V DC type : 21.6 to 26.4V DC (Including supply voltage variation) (Rating : 24V DC) : a) AC type : Maximum 7VA at 100V Maximum 10V at 240V b) 24V AC type : Maximum 5VA c) 24V DC type : Maximum 160mA : Not affected by power failure less than 20msec. otherwise reset to the initial status. : : 0 to 50 (32 to 122 ) : 45 to 85%RH : Approx. 250g, 96(W) x 48(H) x 100(D) mm (1/8 DIN) Free from corrosive and flammable gas and dust. Free from external noise, vibration, shock and exposure to direct sunlight. Backed up non-volatile memory (Data retaining period:Approx. 10years) ¡É ¢µ : a) (0.3%of display value + 1 digit) or 2 (4 ) whichever is larger (Thermocouple) Accuracy is not guaranteed between 0 and 399 0 and 799 ) for type R,S and B input Accuracy is not guaranteed between -199.9 and -100.0 (-199.9 and -158.0 ) for type T,U input b) (0.3%of display value + 1 digit) or 0.8 (1.6 ) whichever is larger (RTD) c) (0.3%of display value + 1 digit) (Voltage, current input) : More than 20M (500V DC) between measured terminals and ground More than 20M (500V DC) between power terminals and ground 1000V AC for one minute between measured terminals and ground 1500V AC for one minute between power terminals and ground
¡¾ : 4 points : Process High, Low (Hold action can be programmed.) : 0 to 100 or 0.0 to 100.0¡É (¢µ ) (Temperature input) 0.0 to 10.0%(Voltage, current input) : Alarm 1,2 : Relay output, From A contact 250V AC 1A (Resistive load) Alarm 3,4 : Relay output, From A contact 250V AC 3A (Resistive load) : 12V DC, +1V, -2V : Max. 2 with the TF and 1 without TF (TF:Transfer switch type) KRKC
|