- 8 models and 9 protective elements |
|
|
|
- Implements 0.5 class measurement precision through a dedicated protection and measurement algorithm. - Displays measurement values using 4-line VFD to allow easy identification. - If an accident occurs, the screen automatically displays the accident situation to show the cause of the accident. | |
| |
|
|
|
- Uses standard protocol Modbus to ensure compatibility of communication. - Use of ProNET-iMC enables high-speed communication. - Adopts composite data transmission method which acquires all data by a single request to improve the response speed of a main system. |
|
|
|
- HRR enables convenient configuration of a monitoring panel via telecommunication, by providing 8 auxiliary input points in addition to CB ON, OFF input whose status is displayed on the front of a relay. |
|
|
|
- Microprocessor and self diagnosis function by hardware improve system reliability. - Has built-in SOE function used to save the accidents and change of values. |
|
|
|
- A single unit includes protection, measurement function, switches and display lamps to simplify wiring work and cost when creating a panel. - One can set the CT and PT ration in 1A and 1V units by manipulating the front key, so they are applicable to all systems. - Draw-out type enabling easy maintenance. - Allows one to know the breaker replacement timing by providing the number of breaking times of a breaker, and conducting period information. |
|
|
|
|
|
Item |
HPR-MD |
HPR-FD |
HPR-TR |
HPR-OC |
HPR-ROC |
|
HPR-FD/G1 |
HPR-FD/S1 |
HPR- FD/G2 |
HPR- FD/S2 |
|
|
Relay Elements |
Under voltage |
Over-current |
Over-current |
Over- current |
Over- current |
Over- current |
Over-current |
Over-current |
Over-current |
Over-current ground |
Selective ground |
(independent 2 units) |
(independent 2 units) |
Over-current ground |
Over-current ground |
Over-current ground |
Over-current ground |
|
|
Over-current ground |
Selective ground |
Percentage differential |
|
AC Reclosing |
Over-voltage |
|
|
independent 2 units) |
(independent 2 units) |
Instantaneous differential |
|
|
Over-voltage ground |
|
|
|
|
|
|
|
|
Display |
Measu rement Item |
Current, voltage, frequency, power factor, active power/energy, reactive power/energy, zero voltage and current |
Current |
Current |
|
Display unit |
VFD (Vaccum Fluorescence Display) (4 lines x 20 char.) |
LCD (4 lines x 20 char.) |
|
I/O |
Digital Input |
10 pts. |
10 pts. |
10 pts. |
10 pts. |
10 pts. |
10 pts. |
7 pts. |
9 pts. |
|
Digital Output |
9 pts. |
6 pts. |
6 pts. |
9 pts. |
9 pts. |
8 pts. |
5 pts. |
9 pts. |
|
Analog Input |
PT:4 pts. CT:4 pts. |
PT:3 pts. CT:4 pts. |
PT:4 pts. CT:4 pts. |
PT:3 pts. CT:8 pts. |
PT:4 pts. CT:8 pts. |
PT:3 pts. CT:7 pts. |
CT:4 pts. |
CT:4 pts. |
|
Comm. |
RS-422 /485 (4/2 Wire) |
1 port |
2 port |
|
RS232 |
1 port |
2 port |
|
Product dimensions (WxHxD:mm) |
325 x 175 x 215 |
375 x 175 x 215 |
195 x 260 x 205 |
164 x 210 x 232 |
|
Weight (kg) |
7.5 |
| |
|
|
|
Item |
HPR |
|
|
Control power |
AC110V / DC 125V |
|
Digital input |
100 ~ 130 VDC / 10 ~ 15 mA / point |
|
Digital output |
Resistive load : AC 250V, 10A DC 30V, 10A COSØ=1.0 |
|
Inductive load : AC 250V, 7.5A DC 30V, 5A COSØ=0.4 L/R=7ms |
|
Analog input |
Current |
CT : 5A, ZCT : 1.5mA |
|
Voltage |
PT : 110V, GPT : 190V |
|
Burden |
PT : 0.5VA or below, CT : 1.0VA or below | | |
|
查看评论 |
|
|
如果您用过本商品,或对本商品有所问题,欢迎发表自己的评论和问题。我们会及时对您提出的问题解答,对您的评论给予鼓励。谢谢对本站的支持。 |
|
|
1.根据您的需要产品,请选定型号;
2.与我司销售人员或技术人员确认您的产品的功能,参数.
3.根据产品名称,产品型号签订购销合同
4.汇款后将汇款底联和合同;收货人地址;开票信息;发货方式传真
直线传真:0760-88306579 分机传真:0760-88886370 88886371 88886372 88886373转807分机
上海办事处传真(FAX): 15382730581 |
售后服务热线:0760-0760-88886370 88886371 88886372 88886373-805 806 803分机 移动电话:15382730581 15377871867
公司直线传真:0760-88306579 公司分机传真:0760-88886370 88886371 88886372 88886373转807分机 联系电话(TEL): 15382730581 15377871867
邮政编码: 528400 公司邮箱:459382380@qq.com 客服QQ:459382380 和 568843411 |